Glossary
Window and door glossary
Window quotes and labels are full of jargon. These are the 51 terms you're most likely to see, in plain English.
| Term | Definition |
|---|---|
| Argon gas | An inert, non-toxic gas sealed between the panes of an insulated glass unit. It slows heat loss better than air. |
| Awning window | A window hinged at the top that opens outward from the bottom. It can stay open in light rain. Awning windows. |
| Bay window | Three windows that project outward from the wall: a large centre window and two angled side windows. |
| Bow window | Four or more equal windows that project from the wall in a gentle curve. |
| Brickmould | The exterior trim around a window or door frame, often wood on older homes. |
| Capping | Aluminum or vinyl wrapped over exterior trim so it never needs painting and resists rot. |
| Casement window | A window hinged on the side that cranks outward. It seals very tightly when closed. Casement windows. |
| Casing | The interior trim around a window or door. |
| Centre-of-glass U-factor | Heat loss measured only at the middle of the glass. It looks better than the whole-window value, so compare whole-window numbers. |
| Condensation | Moisture that forms on cold glass when warm, humid indoor air touches it. |
| Double-hung window | A window with two sashes that both slide up and down. Hung windows. |
| Double-pane window | A window with two layers of glass separated by a sealed space. |
| Egress window | A window large enough to escape through in an emergency, required for basement bedrooms by the Ontario Building Code. |
| Energy Rating (ER) | A Canadian window rating combining heat loss, solar heat gain and air leakage. Higher is better. |
| EnerGuide evaluation | A home energy assessment by a registered energy advisor, often required for Ontario rebates. |
| ENERGY STAR | A certification showing a window or door meets Natural Resources Canada's efficiency requirements. |
| Entry door | The main exterior door into a home, usually steel or fibreglass. Steel entry doors. |
| Fibreglass frame | A strong, low-expansion frame material that holds its shape in temperature swings. |
| Fixed window | A window that does not open. Also called a picture window. |
| French door | A pair of hinged glass doors that open from the centre. |
| Full-frame installation | Removing the entire old window down to the rough opening, then installing a new window and frame. |
| Garden door | A hinged patio door with one operating panel and one fixed panel. Garden doors. |
| Grilles | Decorative bars that divide the glass into sections, often placed between the panes. |
| Head | The top horizontal part of a window frame. |
| Hopper window | A window hinged at the bottom that tilts inward. It is common in basements. Hopper windows. |
| Insulated glass unit (IGU) | The sealed package of two or three panes of glass with spacers and gas fill. |
| Jamb | The vertical sides of a window or door frame. |
| Krypton gas | An inert gas that insulates better than argon. It is often used in thin triple-pane units. |
| Laminated glass | Glass with a plastic layer bonded inside. It holds together when broken and reduces noise. |
| Lintel | The structural beam over a window or door opening that carries the load above it. |
| Low-E coating | A microscopically thin metal coating on glass that reflects heat back into the room in winter and blocks solar heat in summer. |
| Mullion | A vertical or horizontal bar joining two window units together. |
| Multi-point lock | A lock that secures a door at several points along the frame for better security and sealing. |
| Obscure glass | Textured or frosted glass that lets in light while blocking the view, used in bathrooms and entry doors. |
| Retrofit (insert) installation | Installing a new window inside the existing frame, without removing it. |
| Rough opening | The framed hole in the wall that the window or door fits into. |
| Sash | The movable part of a window that holds the glass. |
| Sealed unit failure | When the seal of an insulated glass unit breaks, causing fog or condensation between the panes. |
| SHGC (Solar Heat Gain Coefficient) | The share of the sun's heat that passes through a window, from 0 to 1. |
| Sidelite | A narrow fixed glass panel beside an entry door. |
| Sill | The bottom horizontal part of a window frame. |
| Sliding window | A window with one or more sashes that slide horizontally. Sliding windows. |
| Spacer | The strip that separates the panes of glass around the edge of a sealed unit. |
| Tempered glass | Safety glass that breaks into small, blunt pieces. Required near doors, floors and in other hazardous locations. |
| Transom | A window installed above a door or another window. |
| Triple-pane window | A window with three layers of glass and two sealed spaces, for better insulation and sound control. |
| U-factor | How much heat a window loses, in W/m²·K in Canada. Lower is better. |
| Vinyl frame | A low-maintenance, cost-effective frame made of PVC, the most common choice in Ontario. |
| Visible Transmittance (VT) | The share of visible light that passes through a window, from 0 to 1. |
| Warm-edge spacer | A spacer made from low-conductivity materials that keeps the glass edge warmer and reduces condensation. |
| Weatherstripping | Flexible seals around a window sash or door that block drafts and water. |
Have a term we missed?
Call (416) 990-0609 or send us a message and we'll explain it.
Book your free in-home consultation
We measure every opening, talk through the options that suit your home, and give you a written quote. No pressure, no obligation.